The highly concentrated Surgical Instrument Cleaners & Conditioners.
Contact us for product Literature and pricing.
The easy FOAM-it™lays down a thick blanket of fast acting "high level" multi-tiered Enzymatic Enzyme and Detergent for removing dried on debris from surgical Instruments while cleaning and conditioning the surface of surgical Instruments fast. When water is added for manual or automated cleaning the foam dissipates into lightly colored, Neutral pH, free rinsing Surgical Instrument Cleaners & Conditioners.
Remove stains from surgical instruments.
Prevent pitting and corrosion of surgical instruments.
Clean instruments, or apply treatment to prevent the drying and encrustation of debris, as quickly as possible after use. Do not allow blood and debris to dry on the instruments. If cleaning must be delayed, place groups of instruments in a covered container with appropriate enzyme-detergent or apply an enzyme-detergent foam spray to delay drying. The use of pre-soaking enzyme-detergent foam sprays have been shown to reduce the time expended for manual cleaning and render higher quality outcomes. After surgery, open all box locks and disassemble instruments with removable parts. This will limit blood drying on instruments that may cause them to corrode. The "all-in-one" cleaners and the enzyme-detergent foam sprays deliver a chemical complex to: maintain the hydration of bioburden, prevent corrosion, clean the surface, and condition the surface of instruments & scopes. This can significantly reduce manual cleaning and facilitate cleaning the surface of surgical instruments, scopes, and the lumens of cannulated instruments inside-and-one. If used properly, all-in-one enzyme detergent foam sprays and/or all-in-one "combination" cleaning concentrates can render excellent outcomes and facilitate cleaning instruments and scopes inside-and-out. They effectively cleaning the surface while cleaning lumens and working channels. This can eliminate or reduce the manual labor expended, rendering lower reprocessing costs while improving turnaround.
The reprocessing decontamination process, whether done manually or automatically in a washer-decontaminator- disinfector, can only be effective if cleaning is adequate. Effective disinfection or sterilization: (Generic Sterilization with a Pre-Vacuum Sterilizer (HI-VAC): 270-272° F (132-134° C), 16-minute exposure time, with 4 pulses and a 30-minute dry time. Generic Sterilization with a Gravity Displacement Sterilizer: 270-272° F (132-134° C), 30-minute exposure time, with a 30-minute dry time.) Sterilization of an inadequately cleaned instrument is not possible. Cleaning is the prerequisite for sterilization.
Ultrasonic cleaners are very effective when used with hot water per manufacturer’s recommended temperature and specially formulated detergents. It is recommended that all visible debris and blood be removed from the instrument prior to ultrasonic cleaning.Contact between dissimilar metals can cause corrosion when Ultrasonics is applied. Sort surgical instruments according to similar metal types to prevent corrosion. (electrolytic deposition - galvanic corrosion) It is not recommended to clean plated instruments in an ultrasonic cleaner since the ultrasonic vibration and the presence of other sharp surgery instruments may crack or rupture the plating. Ultrasonic Cleaners do not provide the complete "proper sequence of treatments" i.e. purified final rinse(s) that are purified, purged between treatments and/or have temperatures elevated to disinfection levels. Ultrasonic Cleaning can effectively remove: long term encrustation and surgical cements or glues that have dried onto instrumentation. Overloading, and low water temperature, will decrease the effectiveness of ultrasonic equipment.
Ultrasonic cleaners are most effective when used with hot water per manufacturer’s recommended temperature and with "high level" multi-tiered enzyme detergents. It is recommended that all visible debris and blood be removed from the instrument prior to ultrasonic cleaning. Sort instruments by similar metal for subsequent processing so that electrolytic deposition (galvanic corrosion) due to contact between dissimilar metals will not occur. It is not recommended to clean plated surgery instruments in an ultrasonic cleaner since the ultrasonic vibration and the presence of other sharp instruments may crack or rupture the plating. Always refer to the printed manufacturer recommendations prior to using Ultrasonics.
To maintain moving parts and protect instruments from staining and rusting during sterilization and storage, they should be lubricated with a water-soluble, preserved lubricant after each cleaning. Most automated washer decontaminators provide the option for lubrication at the end of the final rinse treatment. Since effective ultrasonic cleaning removes all lubricant, re-lubrication is important. "all-in-one" cleaning concentrates will provide lubrication. The lubricant should contain a chemical preservative to prevent bacterial growth in the lubricant bath. The bath solution should be made with de-mineralized water. A lubricant containing a rust inhibitor helps prevent electrolytic corrosion of points and edges. Immediately after cleaning, instruments should be immersed or rinsed for 30 seconds and allowed to drain off, not wiped off. A lubricant film will remain through the sterilization to protect surgery instruments during storage.
Staining and spotting may result if residual chemicals are not completely rinsed from surgery instruments that are subjected to steam sterilization. Following the manufacturer’s recommendations for the proper sequence of treatments (cold water pre-wash, enzyme-detergent wash, purified water rinse/lubrication, and drying) is critical to prevent stains and spots. A Cleaning Concentrates that will avoid spotting are "free-rinsing" or "rinse clean".
Studies regarding the "passive oxide layer" of Surgical Instruments
(Guidelines on metals and alloys in contact with food; Council of Europe; published 11.10.2000. Systemic nickel: the contribution made by stainless steel cooking utensils; Contact Dermatitis, Volume 32:2, 1994) of the stainless steel passive layer to prevent corrosion have revealed a reduction in corrosion prevention with the use of cleaning concentrates that are not neutral pH. The use of cleaning concentrates that deliver an acid rinse will release nickel from the stainless steel and decrease the efficacy of the passive layer. This is most critical on initial reprocessing events of stainless steel surgical instruments. Measurable levels of nickel have been detected. It was also shown that, as the number of subsequent uses increased, the level of nickel release diminished and reached a steady state (measured in the order of μg/l). These observations reflect the changes that occur in the passive oxide layer on first immersion of stainless steels in aqueous media.
Stainless steel is essentially a low carbon steel which contains chromium at 10% or more by weight. It is this addition of chromium that gives the steel its unique stainless, corrosion resisting properties. The chromium content of the steel allows the formation of a rough, adherent, invisible, corrosion-resisting chromium oxide film on the steel surface. If damaged mechanically or chemically, this film is self-healing, providing that oxygen, even in very small amounts, is present. The corrosion resistance and other useful properties of the steel are enhanced by increased chromium content and the addition of other elements such as molybdenum, nickel and nitrogen. Stainless steel has a passive film created by the presence of chromium (and often other alloying elements, nickel, molybdenum) that resists this process. When exposed in air, stainless steels passivate naturally (due to the presence of chromium). But the time required can vary. In order to ensure that the passive layer reforms rapidly after pickling, a passivation treatment is performed using a solution of nitric acid and water.
Cleaning Surgical Instruments.
The all-in-ONE™ Enzyme Detergent
Surgical Instrument Cleaners & Conditioners
are the highest concentration Cleaning Concentrate.